GTHA-866

Heat Alarm 10Year Lifetime Battery (optional RF function)

Domestic fire detection alarm

Use battery powered, leak-proof battery design to remind users to install the battery, safe and reliable. No wiring, independent installation, fast and convenient.

Superior design, minimal power consumption, under normal circumstances, the battery can last up to 10 years. The buzzer can emit a high decibel alarm, and the alarm sound within 3 meters is greater than 85dB. Wireless linkage alarm. Photoelectric smoke detection technology, excellent safety performance. With strict quality control and high reliability, it will respond quickly when sensing smoke. Pure white design, easy to match the interior color.

Applicable Scenarios

null

Certification

null

Heat Alarm 10Year Lifetime Battery (optional RF function)
Product Parameters

Model#

GTHA-866

Battery life

10 Year

Voltage

DC3V(Built-in, no need to replace)

Standby current

≤5uA

Sound level

≥85dB@3m

Alarm signal

Sound, RED LED flashing

Size

Ф115×55mm

Use environment

Temperature :-10℃~50℃; Humidity 95% no condensation

Output function

Radio frequency

More Products

Output module

Output module

Standard

GB 16806-2006

Operation voltage

DC24V(18V-28V)

View All
Wireless digital pressure gauge

Wireless digital pressure gauge

Measuring range

Gauge pressure :0~1KPa, 100KPa, 1MPa... 100MPa negative pressure :0~-1KPa, -100KPa Absolute pressure :0~50KPa, 100KPa, 1MPa... 3.5MPa composite pressure :-1KPa~1KPa, -100KPa~20MPa

Long-term stability

≤土0.2%FS/Year

View All
Remote Test Switch

Remote Test Switch

Standard

EN 62479:2010

Voltage

3V

View All
Mounting Pattress

Mounting Pattress

Standard

CE

Sensor

Combined with the main power alarm device

View All
Battery Typed CO Alarm

Battery Typed CO Alarm

Model#

MINI-968D

Battery life

1-10 years

View All
Heat Alarm
Mains Powered with 10 Year Rechargeable Battery Back-up

Heat Alarm Mains Powered with 10 Year Rechargeable Battery Back-up

Wire system

Non-polar bibus

Voltage

220-240VAC

View All
Fire sound and light alarm

Fire sound and light alarm

Standard

GB 26851-2011

Bus voltage

DC24V(18V-28V)

View All
Manual fire alarm button

Manual fire alarm button

Standard

GB 19880-2005

Voltage

DC24V(18V-28V)

View All
Point type optical smoke detector

Point type optical smoke detector

Wire system

Non-polar bibus

Bus voltage

DC24V(18V-28V)

View All
Output module

Output module

Standard

GB 16806-2006

Operation voltage

DC24V(18V-28V)

View All
Wireless digital pressure gauge

Wireless digital pressure gauge

Measuring range

Gauge pressure :0~1KPa, 100KPa, 1MPa... 100MPa negative pressure :0~-1KPa, -100KPa Absolute pressure :0~50KPa, 100KPa, 1MPa... 3.5MPa composite pressure :-1KPa~1KPa, -100KPa~20MPa

Long-term stability

≤土0.2%FS/Year

View All
Remote Test Switch

Remote Test Switch

Standard

EN 62479:2010

Voltage

3V

View All
Mounting Pattress

Mounting Pattress

Standard

CE

Sensor

Combined with the main power alarm device

View All
Battery Typed CO Alarm

Battery Typed CO Alarm

Model#

MINI-968D

Battery life

1-10 years

View All
Heat Alarm
Mains Powered with 10 Year Rechargeable Battery Back-up

Heat Alarm Mains Powered with 10 Year Rechargeable Battery Back-up

Wire system

Non-polar bibus

Voltage

220-240VAC

View All
Fire sound and light alarm

Fire sound and light alarm

Standard

GB 26851-2011

Bus voltage

DC24V(18V-28V)

View All
Manual fire alarm button

Manual fire alarm button

Standard

GB 19880-2005

Voltage

DC24V(18V-28V)

View All
Point type optical smoke detector

Point type optical smoke detector

Wire system

Non-polar bibus

Bus voltage

DC24V(18V-28V)

View All

HOME

ABOUT US

  • ABOUT US
  • MILESTONES
  • BUSINESS STRUCTURE
  • OUR CULTURE

NEWS

PRODUCTS

  • BUSINESS SCOPE
  • PRODUCTS CENTER

SOLUTIONS

  • DOMESTIC FIRE ALARM MONITORING
  • INTELLIGENT FIRE ALARM
  • COMBUSTIBLE GAS DETECTION IOT
  • SMART ELECTRICITY SAFETY WARNING
  • INTELLIGENT FIRE WATER MONITORING

CSR

CASES

JOIN US

  • TALENT PROSPECT
  • MANAGEMENT MODEL
  • WORKING ENVIRONMENT
  • EMPLOYEE EVENTS

CONTACT US

  • Shenzhen Office (SZ)
  • HKSAR Office
  • Logistics Center (HKSAR)
  • SHOP

Copyrights ©2021 GartecTechnology Co., Ltd 嘉达科建. All rights reserved

Copyrights ©2021 GartecTechnology Co., Ltd
嘉达科建. All rights reserved